PerkinElmer N8179194 Mass Spectrometer Mainboard
- Warranty: 365 days
- Quality: Original module
- Condition: New / Used
- Warehouse: Spot
- Delivery time: Shipped in 3 days after payment
- Mailbox:plcvarious@foxmail.com
Introduction
1.Functions
- Central instrument logic control Acts as the master controller of the ICP-MS. Executes the overall instrument operation sequence according to commands sent from the host PC software. Coordinates the ion source, vacuum system, quadrupole mass filter, detector and gas flow modules synchronously.
- Multi-module signal acquisition & communication Collects analog and digital feedback signals from vacuum gauge, plasma power supply, gas mass flow controllers, ion lens power supply and detector amplifier. Communicates with upper workstation via dedicated bus, transmits mass spectrum raw data and instrument status. www.plcva.com
- Hardware interlock & safety protection Monitors vacuum pressure, plasma ignition status, door interlock, cooling water flow and temperature. Triggers safety interlock and protective shutdown automatically if abnormal conditions occur, to prevent damage to the high-vacuum and high-voltage components.
- Real-time parameter configuration Sets and tunes critical working parameters: lens voltage, quadrupole RF/DC voltage, detector gain, argon gas flow, plasma power. Stores instrument calibration constants and fault logs in onboard non-volatile memory.
- System self-diagnosis & alarm reporting Runs power-on self-test (POST) for all peripheral sub-modules. Detects communication failure, sensor faults and hardware anomalies, and pushes error codes to control software for laboratory maintenance troubleshooting.
- Peripheral I/O driving Provides digital I/O ports to control solenoid valves, relays and auxiliary actuators for sample introduction system and vacuum pump chain. www.plcva.com

PerkinElmer N8179194 Mass Spectrometer Mainboard

PerkinElmer N8179194 Mass Spectrometer Mainboard
2. Applications
This PCA is the original spare mainboard for PerkinElmer NexION ICP-MS instruments. plcva.com
Typical Application Scenarios: Commercial testing laboratories, environmental monitoring labs, food safety inspection, semiconductor material analysis, geological & mining testing, pharmaceutical raw material heavy metal detection.
Core Purpose: It serves as the brain of the PE ICP-MS spectrometer. It coordinates all hardware subsystems to complete plasma ionization, ion mass separation and ion signal acquisition for ultra-trace elemental analysis. It guarantees stable mass spectrum data acquisition and instrument safety interlock. It is mainly used for maintenance replacement when the original mainboard fails, to restore normal operation of the NexION ICP-MS instrument.

PerkinElmer N8179194 Mass Spectrometer Mainboard